Of today’s high-end research, Nikon has developed the new Ti series of microscopes. Combined with NIS-Elements imaging software, the Ti supports diverse image acquisition and analysis methods such as multi-dimensional time-lapse imaging to acquire temporal, spatial and spectral information of fast, dynamic live cell processes.
Nikon Eclipse Ti-series TR-NKTI-CAGE-ADP Nikon TE-2000 TR-NKTE-CAGE-ADP Olympus IX71/81 (left port) TR-OLIX-CAGE-ADP Olympus IX73/83 TR-OL83-CAGE-ADP Zeiss Axiovert 200 TR-ZSAV-CAGE-ADP Zeiss Axio Observer TR-ZAXO-CAGE-ADP 4 Cage system adapter Provides a highly modular, seamlessly upgradable and expandable platform for micro-spectroscopy setups. Eclipse LV100NDA - Motorized microscope with episcopic/diascopic illumination. A motorized microscope with episcopic/diascopic illumination,which meets the various needs of observation, inspection, research, and analysis across a wide range of industrial fields. Download manuals, software, and firmware for digital cameras and other imaging devices. Before proceeding, read the description, cautions, and download and installation instructions. No downloads are available for products that are not listed.
486Nikon’s Eclipse TE200/TE300 inverted microscopes are suitable for use in a broad spectrum of application fields. The two models were developed in the late 1990s but are still a good choice for photomicrography applications when combined with our LM digital adapters with plan achromatic precision optics. The TE300 even features a front port, which the lower-priced TE200 doesn’t have. Both models feature a side port, which can be used to attach a DSLR camera, mirrorless system camera or C-mount camera to the microscope.
Illumination with a 30W halogen lamp is standard on the TE200; however, this can be replaced (similar to the TE300) with a 100W illumination pillar. Depending on the model, the light distribution ratio is switchable between 100:0, 20:80 and 0:100.
Both models in the series feature Nikon’s powerful infinity CFI60 optical system. The CFI60 lenses have a parfocal distance of 60 mm, a 25 mm thread size and a 22 mm field of view.
Choice of objectives:
- Achromats
- Plan Fluors
- Plan Fluors with extra-long working distance
- Plan Apochromats
- Hoffman modulation contrast objectives
The well-balanced design of the TE200 and TE300 offers high optical performance, combined with convenient controls for comfortable, fatigue-free operation. In addition to standard observation modes (bright field, dark field and phase contrast), observation techniques such as epi-fluorescence, Hoffman modulation contrast or Nomarski DIC are supported as well. Differential interference contrast (DIC) is a valuable tool for imaging unstained transparent live organisms with high contrast. For cell cultures grown in plastic Petri dishes, the Hoffmann modulation contrast method can be used to produce images with a 3D appearance.
The design is highly modular and provides options for the NT-88NE micromanipulator system, the MHW water-hydraulic micromanipulator for electrophysiology and patchclamp research, an incubator box, discussion equipment, the FX-III series photomicrographic system, a mechanical stage, plate holder, etc.
The sextuple revolving nosepiece of the E600 and E800 microscopes is also compatible with the TE200 and TE300 microscopes. Two mounting options are available: attaching the adapter to the V-T phototube of the side port (option A with 42 mm inner diameter) or removing the V-T phototube and attaching the adapter directly to the tube opening (option B with 38 mm inner diameter). The diagrams below illustrate the two connection methods:
OPTION A: attaching the adapter to the V-T phototube of the side port
OPTION B: attaching the adapter directly to the tube opening
Lutify me download. Available eyepiece tubes are the TE-TL and TE-TS tubes (both are binocular tubes). An intermediate tube (TE-TI) is required for attaching the usual Nikon trinocular tubes (Y-TF and Y-TT). The key to properly attaching a DSLR or system camera to these tubes with our high-quality LM digital adapters is to choose the correct combination:
The following considerations need to be taken into account:
- Does the tube have a Nikon YT-TV adapter (shorter) or a Nikon V-T photo adapter (longer)? These are essential for attaching a camera to the microscope and cannot be bypassed!
- The Nikon YT-TV adapter accepts either the TUST38C LM C-mount adapter or – if you already have one – the Nikon C-mount adapter A (1x). The LM digital adapter, which is connected to the camera, is then added to that combination.
- The LM DSLR adapter is directly attached to the Nikon V-T photo adapter.
- If the microscope doesn’t have a phototube, the camera can also be attached to the eyepiece tube. The image quality is as good as that achieved when attaching the camera to the phototube, and the adapter solution for the eyepiece tube is universal, because it enables compatibility with a wide range of different microscopes. We offer a comprehensive range of products for a large variety of different camera systems.
Conclusion: Equipped with the renowned CFI60 optical system, Nikon’s Eclipse TE200 and TE300 models are very well suited for digital photomicrography.
Does minecraft realms support mods. Photography:
Fitting the microscope to digital single-lens reflex (DSLR), system or C-mount cameras is easy with our LM digital SLR adapters, which feature a plan achromatic optical system. Our products make it possible to capture top-quality microscope images. To help you select the adapter that is right for your camera, we have set up an online configurator on our website. You can also email us – ideally with attached photographs of your microscope.
Modern DSLR and system cameras offer the latest technology and are generally very well suited for microscopy applications. Xmind zen 9 1 for mac free download. Most of them can be controlled remotely via PC/Mac. Because of their high sales volumes, they offer an excellent price/performance ratio compared to special-purpose microscope cameras.
Features of top DSLR and system cameras:
- Large, powerful full-frame sensors (36 x 24 mm)
- Sensor resolution of 50 megapixels
- High light sensitivity (ISO 100,000+)
- Extensive dynamic range (up to 14 aperture stops/f-stops)
- Short exposure times (1/8000 second):
- Full/Ultra HD (4k) video function
- Live video capture on external monitors in ultra HD quality
- Large, powerful full-frame sensors (36 x 24 mm)
- Sensor resolution of 50 megapixels
- High light sensitivity (ISO 100,000+)
- Extensive dynamic range (up to 14 aperture stops/f-stops)
- Short exposure times (1/8000 second):
- Full/Ultra HD (4k) video function
- Live video capture on external monitors in ultra HD quality
In most cases, these cameras are significantly more powerful than microscope cameras with smaller sensors (1/2' or 2/3'). On our website you will find our current camera recommendations and a camera ranking which is specifically tailored to microscopy applications.
New LM Digital Adapter for:Sony Alpha 9 II (ILCE-9M2) / Sony Alpha 9 / Nikon D6 / Sony Alpha 7R IV / Sony Alpha 7S II / Sony Alpha 7R III / Nikon Z6 / Sony Alpha 7R II / Nikon Z7 / Canon EOS R with Canon Adapter EF-EOS R / Canon EOS Ra (Astro) with Canon Adapter EF-EOS R / Canon EOS RP with Canon Adapter EF-EOS R / Sony Alpha 7S / Canon EOS 1D X Mark III / Nikon Z50 / Nikon D850 / Canon EOS 1D X Mark II / Nikon D780 / Sony Alpha 7III / Nikon D5 / Sony Alpha 6600 / Sony Alpha 6400 / Sony Alpha 6100 / Canon EOS 1D X / Nikon D4s / Olympus OM-D E-M5 III / Canon EOS 90D / Canon EOS 5D Mark IV / Nikon D4 / Nikon D750 / Canon EOS 6D Mark II / Fujifilm X-T4 / Fujifilm X-T3 / Sony Alpha 6300 / Sony Alpha 6500 / Nikon D500 / Nikon D810 / Nikon D800 / Canon EOS M6 Mark II / Nikon D800E / Nikon Df / Panasonic Lumix DC-G9 / Nikon D610 / Nikon D600 / Canon EOS 250D / Canon EOS 850D / Rebel T8i / Canon EOS 6D / Sony Alpha 99 II (SLT-A99 II) / Canon EOS M200 / Canon EOS 5DS R ( without low-pass filter) / Olympus OM-D E-M1 Mark II /
AboutObjectivesLED excitationFiltersCamerasSoftwareUser Guide & ManualsPeripheralsThe Nikon Eclipse Ti2-E offers improved system speed, increased flexibility and efficient multi-mode microscopy as part of a fully-integrated microscope system that is ideal for high-end research and live cell imaging. In addition to glass bottom dishes, plastic dishes can be used. The system is especially suited to high-content applications that involve multi-well plates.
Reservation System:Nikon Eclipse Ti2-E
Location: BioCity, 5th floor, room 5149
2x Nikon Plan-Apochromat
• Numerical Aperture: 0.06
• Working Distance: 7.5 mm
• Immersion: Without immersion
10x Nikon CFI Plan-Fluor
• Numerical Aperture: 0.3
• Working Distance: 15.2 mm
• Immersion: Without immersion
20x Nikon CFI S Plan Fluor ELWD
• Numerical Aperture: 0.45
• Working Distance: 8.2-6.9 mm
• Immersion: Without immersion
20x Nikon CFI Plan Apo Lambda
• Numerical Aperture: 0.75
• Working Distance: 1 mm
• Immersion: Without immersion
• Numerical Aperture: 0.06
• Working Distance: 7.5 mm
• Immersion: Without immersion
10x Nikon CFI Plan-Fluor
• Numerical Aperture: 0.3
• Working Distance: 15.2 mm
• Immersion: Without immersion
20x Nikon CFI S Plan Fluor ELWD
• Numerical Aperture: 0.45
• Working Distance: 8.2-6.9 mm
• Immersion: Without immersion
20x Nikon CFI Plan Apo Lambda
• Numerical Aperture: 0.75
• Working Distance: 1 mm
• Immersion: Without immersion
40x Nikon CFI S Plan Fluor ELWD ADM
• Numerical Aperture: 0.6
• Working Distance: 3.6-2.8 mm
• Immersion: Without immersion
60x Nikon CFI Plan Apo Lambda
• Numerical Aperture: 1.4
• Working Distance: 0.13 mm
• Immersion: Oil
100x Nikon Apo TIRF
• Numerical Aperture: 1.49
• Working Distance: 0.12 mm
• Immersion: Oil
The Nikon Ti2-E uses Lumencor Spectra X LED excitation.• Numerical Aperture: 0.6
• Working Distance: 3.6-2.8 mm
• Immersion: Without immersion
60x Nikon CFI Plan Apo Lambda
• Numerical Aperture: 1.4
• Working Distance: 0.13 mm
• Immersion: Oil
100x Nikon Apo TIRF
• Numerical Aperture: 1.49
• Working Distance: 0.12 mm
• Immersion: Oil
- 395nm
- 440nm
- 470nm
- 575nm
- 640nm
- 740nm
- 86006 – CFP/YFP/DsRed
- 84000v2 – DAPI/ FITC/TRITC/Cy5
- 86012v2 – DAPI/FITC/TxRed/Cy5
- 96377 – Cy7-B
- DIC
Orca Emission filters
- DAPI sPx 435/26nm
- CFP 475/20nm
- GFP sPx 515/30nm
- YFP 540/21nm
Nikon Eclipse Ti Manual
- DAPI
- CFP
- GFP
- YFP
- TexasRed
- mCherry 632/60nm
- Cy5 sPx 705/71nm
- Cy7 sPx 809/81nm
2048 x 2048 pixelsNikonDS-Fi3 CMOS (colour)
2880 x 2048 pixelsNIS-Elements AR 5.11.00 64-bit NIS-Elements viewer
Nikon Eclipse Ti Microscope
- Nikon Perfect focus system
- Environment chamber - Okolab
- Temperature control - Okolab